Applications and Occasions
- Sites with vibration analysts, or users with their own analysis programs who need the complete raw signal.
- Early-warning diagnosis and life studies for high-speed equipment (vacuum pumps, water pumps, compressors, blowers, exhaust fans), motors, gear reducers and slide-table conveyors.
- Machine retrofit, acceptance and troubleshooting, or collecting data before moving up to Level 2-4.
Level 1 sensors output raw acceleration and velocity only. They do not include health scoring or alarms; judgement is made by people or software.
Setup and Usage
- Install the sensor with a screw or magnetic base on a bearing housing or motor case, and connect it via RS485 (an RS485-to-USB / Ethernet converter can be used) to a PC or industrial computer.
- Capture raw signals: Level 1 works in Command style - a program sends commands such as sampling settings (rate, duration) and then reads the three-axis raw signals following the command flow, saving them to files. Use the vendor API program (below), or develop your own capture program based on the vendor command protocol.
- Analyze: the saved files are CSV and cannot be opened directly in DynaView. Users analyze them with their own programs or other tools to find the usable frequency band.
- Carry into Level 2 - Level 4: once the band is confirmed, bring it into the sensors and solutions of Level 2 to Level 4 for long-term continuous monitoring.
Sensors and software
- 213MM4-R0: Three-axis, mid-to-high bandwidth, RS485, six sampling rates about 2,666 - 26,667 S/s, software trigger. Matching API: 213MM4-R0 raw signal capture API
- 213MM4-R1: Three-axis, mid-to-high bandwidth, RS485. Matching API: 213MM4-R1 sensor command tool (Python)
- 213ML5-R0: Three-axis, low bandwidth, continuous raw output. Matching API: 213ML5-R0 raw signal capture API
- 413ML6-U0: Three-axis, compact, low bandwidth, continuous raw output. Matching API: 413ML6 raw signal capture program
- API programs: log in as a member and download from Software Download.
- Analysis tools: users analyze the CSV raw data themselves (spreadsheet, Python, MATLAB, etc.).
- Sensor configuration and firmware update: Aurora Modbus Utility (also on the download page).
- Develop your own: ask us for the command protocol to write your own capture program.
- For specifications see each product page; for selection advice contact us.